6. Surge Protection Devices for PV Solar Installations

PV installations must be designed to provide full exposure to the sunlight and hence they are highly vulnerable to the effects of lightning. The capacity of a PV array is directly related to its exposed surface area, so the potential impact of lightning events increases with system size. Where lighting occurrences are frequent, unprotected PV systems can suffer repeated and significant damage to key components. This results in substantial repair and replacement costs, system downtime and the loss of revenue. Properly designed, specified and installed surge protection devices (SPDs) minimize the potential impact of lightning events when used in conjunction with engineered lightning protection systems.

A lightning protection system that incorporates basic elements such as air terminals, proper down conductors, equipotential bonding for all current-carrying components and proper grounding principles provides a canopy of protection against direct strikes. If there is any concern of lightning risk at your PV site, I highly recommend hiring a professional electrical engineer with expertise in this field to provide a risk assessment study and a protection system design if necessary.

It is important to understand the difference between lightning protection systems and SPDs. A lightning protection system’s purpose is to channel a direct lightning strike through substantial current-carrying conductors to earth, thus saving structures and equipment from being in the path of that discharge or being directly struck. SPDs are applied to electrical systems to provide a discharge path to earth to save those systems’ components from being exposed to the high-voltage transients caused by the direct or indirect effects of lightning or power system anomalies. Even with an external lightning protection system in place, without SPDs, the effects of lightning can still cause major damage to components.

Overvoltage may occur in electrical installations for various reasons. It may be caused by:

  • The distribution network as a result of lightning or any work carried out.
  • Lightning strikes (nearby or on buildings and PV installations, or on lightning conductors).
  • Variations in the electrical field due to lightning.

Like all outdoor structures, PV installations are exposed to the risk of lightning which varies from region to region. Preventive and arrest systems and devices should be in place.

The Importance of SPDs

SPDs are particularly important to protect sensitive electrical equipment like AC/DC Inverter, monitoring devices and PV modules, but also other sensitive equipment powered by the 230 VAC electrical distribution network.

Aside from the consequences of direct lightning strikes to the arrays, interconnecting power cabling is very susceptible to electromagnetically induced transients. Transients directly or indirectly caused by lightning, as well as transients generated by utility-switching functions, expose electrical and electronic equipment to very high overvoltages of very short duration (tens to hundreds of microseconds). Exposure to these transient voltages may cause a catastrophic component failure that may be noticeable by mechanical damage and carbon tracking or be unnoticeable but still cause an equipment or system failure.

Long-term exposure to lower-magnitude transients deteriorates dielectric and insulation material in PV system equipment until there is a final breakdown. In addition, voltage transients may appear on measurement, control and communication circuits. These transients may appear to be erroneous signals or information, causing equipment to malfunction or shut down. The strategic placement of SPDs mitigates these issues because they function as shorting or clamping devices.

Technical Characteristics of SPDs

The most common SPD technology used in PV applications is the metal oxide varistor (MOV), which functions as a voltage-clamping device. Other SPD technologies include the silicon avalanche diode, controlled spark gaps and gas discharge tubes. The latter two are switching devices that appear as short circuits or crowbars. Each technology has its own characteristics, making it more or less suitable for a specific application. Combinations of these devices can also be coordinated to provide more optimal characteristics than they offer individually. Table 1 lists the major SPD types used in PV systems and details their general operating characteristics.

An SPD must be able to change states quickly enough for the brief time a transient is present and to discharge the magnitude of the transient current without failing. The device must also minimize the voltage drop across the SPD circuit to protect the equipment it is connected to. Finally, SPD function should not interfere with the normal function of that circuit.

SPD operating characteristics are defined by several parameters that whoever is making the selection for the SPDs must understand. This subject requires more details that can be covered here, but the following are some parameters that should be considered: maximum continuous operating voltage, ac or dc application, nominal discharge current (defined by a magnitude and waveform), voltage-protection level (the terminal voltage that is present when the SPD is discharging a specific current) and temporary overvoltage (a continuous overvoltage that can be applied for a specific time without damaging the SPD).

SPDs using different component technologies can be placed in the same circuits. However, they must be selected with care to ensure energy coordination between them. The component technology with the higher discharge rating must discharge the greatest magnitude of the available transient current while the other component technology reduces the residual transient voltage to a lower magnitude as it discharges a lesser current.

The SPD must have an integral self-protecting device that disconnects it from the circuit should the device fail. To make this disconnection apparent, many SPDs display a flag that indicates its disconnect status. Indicating the SPD’s status via an integral auxiliary set of contacts is an enhanced feature that can provide a signal to a remote location. Another important product characteristic to consider is whether the SPD utilizes a finger-safe, removable module that allows a failed module to be easily replaced without tools or the need to de-energize the circuit.

Read: Surge Protection Considerations

 

Source:

  • http://solarprofessional.com/articles/design-installation/surge-protection-devices-for-pv-installations?v=disable_pagination&nopaging=1#.Wb5DwNMjHdS
  • http://www.electrical-installation.org/enwiki/SPD_for_photovoltaic_applications

Leave a Reply