Type 2 1000V DC SPD – Surge Protection Device Phoenix Contact

Type 2 1000V DC SPD – Surge Protection Device Phoenix Contact

Description

Model No: VAL-MS 1000DC-PV/2+V

Type 2 1000V DC SPD – Surge Protection Device Phoenix Contact

Type 2 1000V DC SPD – Surge Protection Device Phoenix Contact, isolated 1000 V DC voltage systems, for DIN rail mounting, 3-Pos. base element, three plug-in temperature-monitored protective elements, status message on each plug.

The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.

Dimensions

Height89.8 mm
Width53.4 mm
Depth65.7 mm (incl. DIN rail 7.5 mm)
Horizontal pitch3 Div.

Ambient conditions

Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C … 80 °C
Ambient temperature (storage/transport)-40 °C … 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % … 95 %
Shock (operation)60g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)7.5g (5-500 Hz/2.5 h/XYZ)

General

IEC test classificationPV II
PV T2
EN typeT2
SPD failure behaviorOCM (Open-circuit mode)
Connection configurationY configuration
Installation locationInside
AccessibilityAccessible
Installation location of the disconnect deviceInternal
Mode of protection(L+) – (L-)
(L+) – PE
(L-) – PE
Mounting typeDIN rail: 35 mm
Colorjet black RAL 9005
Housing materialPA 6.6-FR
PBT-FR
Degree of pollution2
Distance between live and grounded parts8 mm
Flammability rating according to UL 94V-0
TypeDIN rail module, two-section, divisible
Surge protection fault messageoptical

B

Additional descriptions

NoteThe device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.

B

Protective circuit DC voltage side (DC)

Maximum continuous operating voltage UCPV1170 V DC
Short-circuit current rating ISCPV2000 A
Continuous operating current ICPV< 20 µA
Rated load current IL80 A
Residual current IPE≤ 20 µA DC
≤ 250 µA AC
Standby power consumption PC≤ 25 mVA
Nominal discharge current (8/20) µs15 kA
Maximum discharge current Imax (8/20) µs40 kA
Total discharge current Itotal (8/20) µs40 kA
Voltage protection level Up≤ 3.7 kV
Residual voltage Ures≤ 3.7 kV (at In)
≤ 3.1 kV (at 5 kA)
≤ 3.5 kV (at 10 kA)
≤ 4 kV (at 20 kA)
≤ 4.6 kV (at 30 kA)
≤ 5 kV (at 40 kA)
Response time tA≤ 25 ns
Insulation resistance Riso> 5 GΩ (at 500 V DC)

B

Connection data

Connection methodScrew connection
Screw threadM5
Tightening torque3 Nm (1,5 mm² … 16 mm²)
4.5 Nm (25 mm² … 35 mm²)
Stripping length16 mm
Conductor cross section flexible1.5 mm² … 25 mm²
Conductor cross section solid1.5 mm² … 35 mm²
Conductor cross section AWG15 … 2
Connection methodFork-type cable lug
Conductor cross section flexible1.5 mm² … 16 mm²

B

UL specifications

SPD Type1CA
Maximum continuous operating voltage MCOV1170 V DC
Nominal voltage1170 V DC
Mode of protection(L+) – (L-)
(L+) – G
(L-) – G
Power distribution systemDC PV
Voltage protection rating VPR3 kV
Nominal discharge current In10 kA
Short-circuit current rating (SCCR)50 kA